ADL3000-E 3-Phase Energy Meter


■ Measurement: three-phase kWh, kvarh, U, I, P, Q, S, PF, F

Current input: 3 × 1(6)A, 3 × 10(80)A(direct)

■ Programmable keys, LCD Display

■ Communication: Max. 2 pcs of RS485 interface

■ Digital input/output

Temperature monitor: NTC sensors

Harmonic: 2~31st and total Harmonic

■ Certificates: IEC; CE;
description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
Description

  ■ Measurement:

        kWh(2 directions), kvarh(2 directions), kWh of every phase

        U, I, P, Q, S, PF, F

  ■ Harmonic: 2~31st and total Harmonic

  ■ LCD Display, Back linght

  ■ HMI, programable buttons, Back linght

        Code, Protocol, Address, Baud rate, Parity, CT/PT Ratio 

  ■ Active energy pulse output

  ■ Digital input, Digital output

  ■ Alarms: Undervoltage, overvoltage

  ■ Temperature monitor: NTC sensors

  ■ Infrared communication

  ■ Max.2 pcs RS485 communication port(Modbus RTU)

  ■ Multi-rate/Flexible Tariff:

        4 time zones, 4 tariff rate (Spike, Peak, Flat, Valley)

        2 time periods list, 14 time periods in day

  ■ Data Function: Frozen Data(last 48 months or last 90 days),Max Demand

  ■ Din rail mounted meter

Technical Parameters

■ Connection types: 3 phases 4 wires, 3 phases 3 wires, 

■ Input voltage: 3×57.7/100 V, 3×220/380 V, 3×100 V, 3×380 V

   Frequency: 45~65Hz

   Power consumption: < 10 VA(every phase)

■ Input current: 3 × 1(6)A, 3 × 10(80)A

                          3 × 1(6)A(provided with CTs) 

                          3 × 10(100)A(provided with CTs) 

   Consumption: < 1 VA(every phase)

■ Temperature monitor: NTC sensors, for 3 circuits, -40℃~99℃

■ Accuracy:

           kWh: 0.5S  class

           kvarh: 2.0  class

■ Digital input: quantity: 1

   Digital output: quantity: 1

■ Range of measuring: 000000.00~99999999kWh

■ Active energy pulse: 

           Pulse width: 80±20ms

           Pulse constant: 6400imp/kWh, 400imp/kWh

Communication: Interface RS485, Modbus RTU protocol, 1200bps~19200bps

■ Work Environment: 

           Work temperature: -25℃~55℃

           Relative humidity: ≤95%(No condensation)

           Altitude: <2000m

Model Selection

Basic model:

        Provided without CT:

                ADL3000-E/C

        Provided with CT:

                ADL3000-E/CT C

 

■ Optional function:(Place as your technical requirements)

        Tariff: F

        Digital input/output: K

        Temperature monitor: T

        Measurement harmonic: H

        Second port: 2C

 

Selected model

        ADL3000-E/C K H

CONTACT US