■ Measurement: three-phase kWh, kvarh, U, I, P, Q, S, PF, F
■ Input current: 3 x 1(6)A AC (via CTs)
■ Programmable keys, LCD/LED Display
■ Digital input/output
■ Analog quantity output
■ Events record
■ Harmonic: 2~31st and total Harmonic
■ Tariff: 4 kinds
■ Communication: RS485 (MODBUS-RTU protocol)
■ Certificates: IEC; CE;
■ Connection Types: 3 phases 4 wires, 3 phases 3 wires,
■ Input voltage:
single-phase: AC 100V, 400V
three-phase: AC 3×57.7/100V, 3×220/380V, 3×380/660V, 3×100V, 3×380V, 3×660V
Power consumption: < 0.5 VA(every phase)
Overload: 1.2 times(working normal), 2 times 1 s.
■ Frequency: 45~65Hz
■ Input current: 3×1(6)A
Overload: 1.2 times(working normal), 10 times 1 s.
Consumption: < 0.5 VA(every phase)
■ Accuracy:
kWh: 0.5 class
kvarh: 1.0 class
■ Power supply: AC 85~265V
DC 24V(±20%)
DC 48V(±20%)
Consumption: < 10 VA
■ Digital input: quantity: Max.4
Digital output: quantity: 2
■ Analog quantity output: quantity: 1, 4~20mA
■ Range of measuring: 000000.00~99999999kWh
■ Active energy pulse:
Pulse constant: 10000imp/kWh
■ Communication: Interface RS485 (Modbus-RTU)
■ Work Environment:
Work temperature: -25℃ ~ 55℃
Relative humidity: ≤ 95%(No condensation)
Altitude: <2000m
SunTower Project
The Sun Tower project in Bangkok deployed a cloud-based solution with meters, gateways, and platform to enable remote electricity monitoring, real-time fault alerts, automated meter reading, and energy analysis across office and commercial floors.
EV Charger Project
The project for Chargers in Spain deployed the Acrel DJSF1352-RN/D DC meters, ADL200 single-phase meters, and ADL400 three-phase meters, providing integrated energy monitoring and management solutions with a total project value of approximately $250,000.
Basic Model: (Please be noted, CTs doesn't provide with meter.)
AMC - serise code
Outline Dimension:
72: 72 x 72 mm
96: 96 x 96 mm
Display: L - LCD; if with out leter "L", it will be LED.
Monitor of singe-phase power: E
Monitor of three-phase power: E3(connection type: 3 phase 3 wires)
E4(connection type: 3 phase 4 wires)
Notes: {2 DI(digital input) + 2 DO(digital output) + 1 Ep(active pulse)}: K
+ 1 interface of communication RS485(C) have been equipped.
Selected basic model:
AMC96L-E4 KC
Optional function:(Place as your technical requirements)
Digital input/output: K: Q-ty of DI: 4, Q-ty of DO: 2(Please highlight 4DI + 2DO, when placing an order.)
F: Tariff
H: 2~31st and total Harmonic measurement
M: Analog quantity output
Finial selected model:
AMC96L-E4 KC M, 2 DI + 2 DO +1 Ep