ASJ10L-LD1C Residual Current Operated Relay

 

■ Application: AC type of residual current measurement

■ Alarm (>=100 % of the set response value IΔn)

■ Rated residual operated current (configurable)

■ Non-operated time limit(configurable)

■ 2 pcs relay outputs (configurable)

■ Distant&Local Test & Reset

■ DIN rail mounting type

description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
Application aims

    The Residual Current Operated Relay is designed for fault and residual current monitoring in earthed power supply systems (TN and TT systems) where an alarm is to be activated in the event of a fault, but disconnection must be prevented. 

    The prewarning stage (50…100 % of the set response value IΔn) allow to distinguish between prewarning and alarm. Since the values are measured with current transformers, the device is nearly independent of the load current and the nominal voltage of the system.

 

■ Residual current monitoring in earthed two, three or four conductor systems
■ Current monitoring of single conductors de-energised
■ Socket-outlet circuits for devices
■ Alarm systems, safety devices
■ Air conditioning systems
■ Monitoring of earthed power supplies for stray currents
■ Impact on N conductors
■ Trace heating systems

Customer Story

SunTower Project

The Sun Tower project in Bangkok deployed a cloud-based solution with meters, gateways, and platform to enable remote electricity monitoring, real-time fault alerts, automated meter reading, and energy analysis across office and commercial floors.

LEARN MORE

EV Charger Project

The project for Chargers in Spain deployed the Acrel DJSF1352-RN/D DC meters, ADL200 single-phase meters, and ADL400 three-phase meters, providing integrated energy monitoring and management solutions with a total project value of approximately $250,000.

LEARN MORE
Technical parameters
Type of residual current AC
Power supply Voltage AC110V (±10%), AC220V (±10%)
Power consumption No more than 5W
Вход Rated residual operated current I△n 0.03, 0.1, 0.3, 0.5(A)
 Time limit of  nun-operation △t 0.1, 0.5(s)
Rated residual nun-operation current I△no 50%In
Operation type AC sinusoidal current
Frequency 50 Hz ± 5 Hz
Margin of error -20% ~ -10%In
Output Output type 1 NO + 1 changeover
Contact capacity 5A 250V AC; 5A 30V DC
Reset type Local&distant
Working environment Temperature -20℃~+55℃
Related humidity No more than 95% RH
Application Structure

Explore Acrel’s Solutions Now!

Empowering Smarter Energy Management for a Sustainable Future.