ASJ60 Series Residual Current Operated Relay

 

■ Application: AC and A types of residual current measurement

■ Max.16 circuits residual current monitoring(1mA-30A)

■ Separately adjustable response values(for each circuit)

■ Max.16 circuits residual current alarm relay

■ 2 pcs digital inputs

■ Communication: RS485, 4G

■ Events record (Max. 30 pcs)

■ DIN rail mounting type

description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
Selection

       ASJ60 – LD X1 X2 / X3

       ASJ60 – LD —— Residual Current Monitoring Device

       X1 ——  Monitoring cirtuits, Max.16

       X2 —— A: AC sinusoidal current, DC impulse current

                    C: AC sinusoidal current

       X3 —— Communication type: C: RS485(Modbus RTU protocol) or 4G: 4G

Selected model: 

       ASJ60 – LD 16 A C

Customer Story

SunTower Project

The Sun Tower project in Bangkok deployed a cloud-based solution with meters, gateways, and platform to enable remote electricity monitoring, real-time fault alerts, automated meter reading, and energy analysis across office and commercial floors.

LEARN MORE

EV Charger Project

The project for Chargers in Spain deployed the Acrel DJSF1352-RN/D DC meters, ADL200 single-phase meters, and ADL400 three-phase meters, providing integrated energy monitoring and management solutions with a total project value of approximately $250,000.

LEARN MORE
Application aims

    The Residual Current Operated Relay is designed for fault and residual current monitoring in earthed power supply systems (TN-S and TT systems) where an alarm is to be activated in the event of a fault, but disconnection must be prevented. 

    The prewarning stage (50…100 % of the set response value IΔn) allow to distinguish between prewarning and alarm. Since the values are measured with current transformers, the device is nearly independent of the load current and the nominal voltage of the system.

 

■ Lighting systems

■ Residual current monitoring in earthed two, three or four conductor systems

■ Current monitoring of single conductors de-energised

■ Socket-outlet circuits for devices

■ Alarm systems, safety devices

■ Air conditioning systems

■ Monitoring of earthed power supplies for stray currents

■ Impact on N conductors

■ Trace heating systems

Technical parameters
Type of residual current A or AC
Power supply Voltage AC/DC 85~265V
Power consumption No more than 10VA
Вход Monitoring circuit q-ty Max.16
Measurement range of residual current 0.001~30(A)
Rated residual operation current I△n 0.001~30(A)
Operation type AC sinusoidal current, DC impulse current
OR AC sinusoidal current,
Frequency 50 Hz ± 5 Hz
Rated residual non-operation current I△no 0~10s
DI 2 pcs passive dry contacts input
Output Output type Max.16 circuits residual current alarm relay(NO)
1 circuit waterlogged alarm relay
Contact capacity 5A 250V AC; 5A 30V DC
Reclosing Reclosing times 0~99(adjustable)
Time interval 0~999s(adjustable)
Communication Type 1 RS485 port, Modbus-RTU protocol
Type 2 4G
Working environment Temperature -20℃~+55℃
Related humidity No more than 95% RH

Explore Acrel’s Solutions Now!

Empowering Smarter Energy Management for a Sustainable Future.