Zero Export Device Solar System Acrel ACR10R-D16TE Single Phase Solar Inverter Reverse Power Monitor Meter

● Measures active kWh (positive and negative), Reactive kWh (positive and negative), Apparent kWh (positive and negative),U, I, P, Q, S, PF, F, etc.
● Accuracy: Class 0.5
● Rated current: 80A, 120A, 200A, 300A
● 12 bits section LCD display, background light
● 3 keys to communication and set parameters
● Rated voltage: 220V(±20%)
● Rated current: 80A, 120A, 200A, 300A
● Power supply: AC85-265V, or DC100-350V; DC24V(±10%); DC48V(±10%)
● Standard & Certificate: CE, etc.

description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
Overview

ACR10R Bidirectional Single-phase Solar Pv Energy Meter with External CT

    

(Note: The meter can match to Solis Inverter to solar power zero export, if it is used for the Solis Inverter)
    
Single or three phase LCD din rail energy meter with 36mm split CT enabled cable 300A input. It is suitable for power monitoring of grid-connected PV power stations, power management, and so on. It is easy to install without removing the primary bus bar and is cost-effective. It can measure current, voltage, active power, reactive power, frequency, power factor, and so on. It supports multi-tariff energy metering, 4-quadrant energy metering, and so on.

   
     

Measurement: 1-phase Active Power, Reactive Power, Current, Voltage and etc 15 Kwp available

Current Rating:

Diameter 10mm,80A (paired with external CTs)

Diameter 16mm,120A (paired with external CTs)

Diameter 24mm,200A (paired with external CTs)

Diameter 36mm,300A (paired with external CTs)

 Communication: RS485 (MODBUS-RTU)

 Application: Using distributed Solar PV and Anti-reflux Inverter

 Display: LCD Display

 Installation: 35mm DIN Rail

 Power Supply: 85~265V AC or 100~350V DC

 Standard&Certificate: CE
    

Product Parameters

Technical parameters
Indicators
 
 
 
 
 
 
 
Input
Grid
Single-phase
Frequency
45~65Hz
 
 
Voltage
Rated voltage: AC 100V, 400V
Overload: 1.2 times the rated voltage(continuous); 2 times the rated voltage lasting for 1 second
Power consumption: less than 0.2VA
 
 
Current
Rated current: 10A,20A,40A,80A,120A,200A etc. (for details see product specifications)
Overload: 1.2 times the rated current(continuous);10 times the rated current lasting for 1 second
Power consumption: less than 0.2VA
 
Output
Communication
RS485 interface, Modbus-RTU
Display
LCD
Measurement precision
Voltage: 0.2 level, current, power Active energy: 0.5 level,0.01Hz frequency, Reactive energy: 1 level
Power supply
AC85~265V or DC100~350V; power consumption ≤10VA
 
 
Safety
Power frequency withstands voltage
AC2kV 1 min between power supply // current input//voltage input and communication AC2kV 1 min between each pair of combinations
among power supply, current input, and voltage input.
Insulating resistor
 Input, output terminal to housing >100MΩ
Environment
Working temperature: -10ºC~+55ºC;storage temperature: -20ºC~+70ºC
Relative humidity:5%~95%,non-condensing; altitude:≤2500m
  

Display

     


 
Acrel ACR10r-D16te Single Phase DIN Rail Kwh Meter for PV System

   

Detailed Photos

 
Acrel ACR10r-D16te Single Phase DIN Rail Kwh Meter for PV System

Features

 

 
 
 
 
 
 
Acrel ACR10r-D16te Single Phase DIN Rail Kwh Meter for PV System

Used for distributed Solar PV

Reflux Monitoring 

Acrel ACR10r-D16te Single Phase DIN Rail Kwh Meter for PV System

Bidirectional Metering

 Active Energy Metering

 Reactive Energy Metering

Acrel ACR10r-D16te Single Phase DIN Rail Kwh Meter for PV System

RS485 Communication

 MODBUS-RTU Protocol

 Communicate with Inverter to realize anti-reflux Function

 

Acrel ACR10r-D16te Single Phase DIN Rail Kwh Meter for PV System

Single-phase Two-Wire Connection

 Paired with external split core CT

 Rated Voltage: AC 100V, 400V

Acrel ACR10r-D16te Single Phase DIN Rail Kwh Meter for PV System

LCD Display

 Parameter Display

 Programming Interface

Acrel ACR10r-D16te Single Phase DIN Rail Kwh Meter for PV System

Keypads HMI for Programming

 Parameter Display Setting

 Communication(address, baud rate and etc.)

 

 

Technical parameters
Indicators
 
 
 
 
 
 
 
Input
Grid
Single-phase
Frequency
45~65Hz
 
 
Voltage
Rated voltage: AC 100V, 400V
Overload: 1.2 times the rated voltage(continuous); 2 times the rated voltage lasting for 1 second
Power consumption: less than 0.2VA
 
 
Current
Rated current: 10A,20A,40A,80A,120A,200A etc. (for details see product specifications)
Overload: 1.2 times the rated current(continuous);10 times the rated current lasting for 1 second
Power consumption: less than 0.2VA
 
Output
Communication
RS485 interface, Modbus-RTU
Display
LCD
Measurement precision
Voltage: 0.2 level, current, power Active energy: 0.5 level,0.01Hz frequency, Reactive energy: 1 level
Power supply
AC85~265V or DC100~350V; power consumption ≤10VA
 
 
Safety
Power frequency withstands voltage
AC2kV 1 min between power supply // current input//voltage input and communication AC2kV 1 min between each pair of combinations
among power supply, current input, and voltage input.
Insulating resistor
 Input, output terminal to housing >100MΩ
Environment
Working temperature: -10ºC~+55ºC;storage temperature: -20ºC~+70ºC
Relative humidity:5%~95%,non-condensing; altitude:≤2500m
 

Wiring Chart

Acrel ACR10r-D16te Single Phase DIN Rail Kwh Meter for PV System

Dimension

Acrel ACR10r-D16te Single Phase DIN Rail Kwh Meter for PV System

Typical Application

 

 Acrel ACR10r-D16te Single Phase DIN Rail Kwh Meter for PV System

Explore Acrel’s Solutions Now!

Empowering Smarter Energy Management for a Sustainable Future.