AIM Series IT System Insulation Monitor Device

 

Application: IT system

■ Usage: monitor ground insulation of IT system

■ Used with AID series, AIL series, ASG150, AKH-0.66P26

■ Communication: RS485(Modbus RTU), CAN

■ Support Insulation Fault Location Function

■ Standards: IEC 61557-8-2007, IEC 60364-7-710: 2002

(Photos of AIM - M 200)

description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
Key Functions

  ■ IT system insulation Resistance monitoring

  ■ Insulation Fault Location Function (Used with AIL150 series devices)

  ■ Load current &Temperature monitor of insulation Transformer

  ■ Prompt Alarm with Relay Output

  ■ LED Indicator(alarm)

  ■ HMI, programable buttons, Back linght

  ■ LCD Display, Back linght

  ■ Communication: RS485 port, CAN port(Only AIM-M200)

  ■ Din rail mounted device

Customer Story

SunTower Project

The Sun Tower project in Bangkok deployed a cloud-based solution with meters, gateways, and platform to enable remote electricity monitoring, real-time fault alerts, automated meter reading, and energy analysis across office and commercial floors.

LEARN MORE

EV Charger Project

The project for Chargers in Spain deployed the Acrel DJSF1352-RN/D DC meters, ADL200 single-phase meters, and ADL400 three-phase meters, providing integrated energy monitoring and management solutions with a total project value of approximately $250,000.

LEARN MORE
Technical Parameters
Model AIM-M10 AIM-M100 AIM-M200
Power supply Voltage AC 220V±10% DC 24V ± 25%
Frequency 50/60Hz -
Power consumption < 5W < 8W < 3W
Insulation monitor Insulation resistance 10-999kΩ
Accuracy 0—±10%
Alarm 10—995kΩ 50—999kΩ 50—999kΩ
Response time <2s
Measuring voltage <12V
Measuring current <42uA <50uA <50uA
Current monitor Range 2.1-50A
Alarm value 5-50A
Accuracy ≤±5%
Temperature monitor Sensor type PT100
Range -50—+200℃
Alarm value 0—+200℃
Alarm output Output types 1 port of relay 2 ports of relay
(programmable)
2 ports of relay
(No programmable)
Contact capacity AC 250V/3A  AC 250V/3A   AC 250V/3A   DC 30V/3A
Work environment Work temperature -10—+55℃
Storage temperature -20—+70℃
 Relative humidity 5%-95%, no condensation
Altitude ≤2500m
Communication 1 port of RS485, Modbus-RTU 2 ports of RS485, Modbus-RTU 1 port of CAN
Model Selection

  AIM-M X1

  AIM-M ― series

  X1 ― Device dimension(LxWxH mm)

             10: 85x54x63.6 

             100: 85x107.3x74.7

             200: 85x107.3x74.7

  Example for placing order:

  IT system insulation monitor deviceAIM-M - 200

Wiring Diagram