■ Application: IT system
■ Usage: monitor ground insulation of IT system
■ Used with AID series, AIL series, ASG150, AKH-0.66P26
■ Communication: RS485(Modbus RTU), CAN
■ Support Insulation Fault Location Function
■ Standards: IEC 61557-8-2007, IEC 60364-7-710: 2002
(Photos of AIM - M 200)
■ IT system insulation Resistance monitoring
■ Insulation Fault Location Function (Used with AIL150 series devices)
■ Load current &Temperature monitor of insulation Transformer
■ Prompt Alarm with Relay Output
■ LED Indicator(alarm)
■ HMI, programable buttons, Back linght
■ LCD Display, Back linght
■ Communication: RS485 port, CAN port(Only AIM-M200)
■ Din rail mounted device
SunTower Project
The Sun Tower project in Bangkok deployed a cloud-based solution with meters, gateways, and platform to enable remote electricity monitoring, real-time fault alerts, automated meter reading, and energy analysis across office and commercial floors.
EV Charger Project
The project for Chargers in Spain deployed the Acrel DJSF1352-RN/D DC meters, ADL200 single-phase meters, and ADL400 three-phase meters, providing integrated energy monitoring and management solutions with a total project value of approximately $250,000.
| Model | AIM-M10 | AIM-M100 | AIM-M200 | |
| Power supply | Voltage | AC 220V±10% | DC 24V ± 25% | |
| Frequency | 50/60Hz | - | ||
| Power consumption | < 5W | < 8W | < 3W | |
| Insulation monitor | Insulation resistance | 10-999kΩ | ||
| Accuracy | 0—±10% | |||
| Alarm | 10—995kΩ | 50—999kΩ | 50—999kΩ | |
| Response time | <2s | |||
| Measuring voltage | <12V | |||
| Measuring current | <42uA | <50uA | <50uA | |
| Current monitor | Range | 2.1-50A | ||
| Alarm value | 5-50A | |||
| Accuracy | ≤±5% | |||
| Temperature monitor | Sensor type | PT100 | ||
| Range | -50—+200℃ | |||
| Alarm value | 0—+200℃ | |||
| Alarm output | Output types | 1 port of relay | 2 ports of relay (programmable) |
2 ports of relay (No programmable) |
| Contact capacity | AC 250V/3A | AC 250V/3A | AC 250V/3A DC 30V/3A | |
| Work environment | Work temperature | -10—+55℃ | ||
| Storage temperature | -20—+70℃ | |||
| Relative humidity | 5%-95%, no condensation | |||
| Altitude | ≤2500m | |||
| Communication | 1 port of RS485, Modbus-RTU | 2 ports of RS485, Modbus-RTU | 1 port of CAN | |
AIM-M X1
AIM-M ― series
X1 ― Device dimension(LxWxH mm)
10: 85x54x63.6
100: 85x107.3x74.7
200: 85x107.3x74.7
Example for placing order:
IT system insulation monitor deviceAIM-M - 200


Empowering Smarter Energy Management for a Sustainable Future.